Description
- Refrigerated & Humidity Condition for Seed.
- Better Mineral Puf Insulated to keep the surface Temp. of Body comfortable & Avoid cooling loss
- Silent energy saving Kirloskar/ Tecumseh Compressor designed to circulate uniform Air Throughout the chamber with better imported coil condenser / copper coil improved Temperature distribution
- Polish 304 grade S. Steel interior corrosion resistant long life operation having adjustable shelves to make more space for different height
- Kanthal A-1 tubular heater is fitted with for better accuracy
- Tubular type Kanthal A-1 Immersion heater are fitted at the bottom of tank for humidity purpose
- Windowed Front glass door, Also outer MS powder Coated door & inner full view Acrylic door to observe the Test process inside the seed Germinator as desired while keep Temp. of Humidity un-interrupted.
- Full feature Digital Temp. controller Cum Indicator with Voltmeter.
Optional : 1) Digital Temp. & Digital Humidity Controller.
2) Digital Voltmeter - Angle Iron frame with castor wheel for easy movement.
- 2 Side extra door with exterior lighting arrangement (06 Nos. Fluorescent Tube Light) with Copper choke & Starter.
- 24 Hrs. Cyclic Timer to control the Illumination i.e. 6 Tube light.
- Humidistate to control Humidity (On customer request) •Safety Controller are provide with the Digital Temp. Controller. Fitted with 2 Nos. Fan (one for heating & one for cooling)
Applications
Useful for Conducting various experiment on variety of seeds. Can be use as incubator.
Specifications
Model |
JDS 1.11 | JDS 1.11 A |
Capacity (Ltrs.) | 308 | 616 |
Interior (mm) | 555 x 910 x 605 | 555 x 910 x 605 (2 Different Chambers) |
Heater Wattage “W” | 250 W | 250 x 2 = 500 W |
Humidity Heater wattage “W” | 1.5 K W | 1.5 K W x 2 |
Shelves | 6 Nos. & 14 Nos. | 6 Nos. x 2, 14 Nos. x 2 |
* Dimensions are expressed in (Width x Depth x Height)
Technical Parameters
Control Panel: | Voltmeter, Mains, Humidity Indicator, Illumination L & R, 24 Hrs. Timer & Digital Temp./ Humidit Controller |
Power Consumption: | 220/ 230V AC supply +- 10% 50Hz. Single Phase |
Safety Function: | Temp. Overshoot/ Failure Control |
Housing Material : | CRC / Mild Steel duly power Coated |
Optional: | Double Colour Gate, Top & Grill |
Temperature Stability : | +-0.5°C |
Humidity Control: | By Humidistate/ Digital |
Refrigerant: | R 134 |
Compressor: | Heavy duty Kirloskar/ Tecumseh |
Optional: |
|
Duty Cycle: | Continuous |
Interior: | S.S 304 grade with glass window for illumination condition on the both side |
Precaution: | Don’t use the Instrument without water. Check water level at regular interval |